terça-feira, 18 de junho de 2013
segunda-feira, 17 de junho de 2013
Int Endod J June 2013 - Shaping ability of different single-file systems in severely curved root canals of extracted teeth
Abstract
Burklein S, Benten S, Scha€fer E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. International Endodontic Journal, 46, 590–597, 2013.
Aim
To compare the shaping ability of three different single-file systems with Mtwo rotary instruments dur- ing the preparation of curved root canals in extracted teeth.
Methodology
A total of 80 root canals with cur- vatures ranging between 25° and 35° were divided into four groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared to the following apical sizes: Mtwo: size 30 using the single-length technique; Reciproc, F360, and OneShape: size 25. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis programme. Preparation time, changes in working length, and instrument failures were also recorded. These data were analysed statistically using ANOVA and Student–Newman–Keuls test.
Results
During preparation, no file fractured. All instruments maintained the original canal curvature well with no significant differences between the instrument systems (P = 0.792). Instrumentation with Reciproc and OneShape was significantly faster than with F360 and Mtwo (P < 0.05), while F360 was significantly faster than Mtwo (P < 0.05). No significant differences were obtained regarding changes in working length during instrumentation with the different instruments (P = 0.784).
Conclusion
Under the conditions of this study, all instruments respected the original canal curvature well and were safe to use. The use of Reciproc and OneShape instruments required less time to prepare the curved canals compared with Mtwo and F360.
Keywords: canal curvature, canal straightening,
F360, OneShape, reciprocal motion.
Burklein S, Benten S, Scha€fer E. Shaping ability of different single-file systems in severely curved root canals of extracted teeth. International Endodontic Journal, 46, 590–597, 2013.
Aim
To compare the shaping ability of three different single-file systems with Mtwo rotary instruments dur- ing the preparation of curved root canals in extracted teeth.
Methodology
A total of 80 root canals with cur- vatures ranging between 25° and 35° were divided into four groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the radius of canal curvature. Canals were prepared to the following apical sizes: Mtwo: size 30 using the single-length technique; Reciproc, F360, and OneShape: size 25. Using pre- and post-instrumentation radiographs, straightening of the canal curvatures was determined with a computer image analysis programme. Preparation time, changes in working length, and instrument failures were also recorded. These data were analysed statistically using ANOVA and Student–Newman–Keuls test.
Results
During preparation, no file fractured. All instruments maintained the original canal curvature well with no significant differences between the instrument systems (P = 0.792). Instrumentation with Reciproc and OneShape was significantly faster than with F360 and Mtwo (P < 0.05), while F360 was significantly faster than Mtwo (P < 0.05). No significant differences were obtained regarding changes in working length during instrumentation with the different instruments (P = 0.784).
Conclusion
Under the conditions of this study, all instruments respected the original canal curvature well and were safe to use. The use of Reciproc and OneShape instruments required less time to prepare the curved canals compared with Mtwo and F360.
sábado, 15 de junho de 2013
quinta-feira, 13 de junho de 2013
quarta-feira, 12 de junho de 2013
Caso Clínico da Aluna de Especialização em Endodontia da EEC - Cristina Borba - Retratamento Endodôntico 11
Desobturação com Protaper D
Reintrumentação com Protaper Universal (F5)
Obturação com Híbrida de Tagger
Cristina Borba
domingo, 9 de junho de 2013
Aula do Prof. Carlos E. Fontana no Curso de Especialização em Endodontia da ABO-Santos
No último dia 05 de junho o Prof. Carlos E. Fontana (Equipe de Endodontia de Campinas) esteve na ABO-Santos no curso de Especialização em Endodontia para ministrar uma aula seguida por um hands-on do sistemas Rotatório Mtwo e Reciprocante Reciproc.
O convite foi feito pela Equipe EndoSantos , Profa. Luciana Magrin Blank Gonçalves , Prof. Luiz Antônio B. Sapia e Prof. Guilherme Henrique R Martins.
Alex da Endovirtual colaborou com as atividades.
quinta-feira, 6 de junho de 2013
Defesa de Mestrado em Endodontia - Paula Daniela dos Reis Vieira
Dissertação: Avaliação de três sistemas rotatórios de níquel-titânio na desobturação de canais radiculares. Estudo em microscopia eletrônica de varredura.
Banca:
Prof. Alexandre Sigrist De Martin- presidente;
Prof. Carlos Eduardo da Silveira Bueno- 1o membro
Prof. Daniel Rocha - membro externo
Banca:
Prof. Alexandre Sigrist De Martin- presidente;
Prof. Carlos Eduardo da Silveira Bueno- 1o membro
Prof. Daniel Rocha - membro externo
terça-feira, 4 de junho de 2013
Aula do Prof. Daniel Kherlakian (Endogroup) no curso de Mestrado em Endodontia da Equipe de Endodontia de Campinas
No dia 03/06 o Prof. Daniel Kherlakian esteve na São Leopoldo Mandic no curso de Mestrado em Endodontia da EEC para ministrar mais uma vez a aula de "Reintervenções em Endodontia".
segunda-feira, 3 de junho de 2013
Prof. Betina Bassrani - Equipe de Endodontia de Campinas e alunos na UNIODONTO CAMPINAS
No dia 03/06/13 através do apoio da Dentsply a Prof. Betina Bassrani (University of Toronto - Canadá) esteve na Uniodonto Campinas apresentando as novas perspectivas da Instrumentaçao e Irrigação na Endodontia.
A Equipe de Endodontia de Campinas e seus alunos também participaram do evento.
domingo, 2 de junho de 2013
JOE June 2013 - Success of Ultrasonic Technique in Removing Fractured Rotary Nickel-Titanium Endodontic Instruments from Root Canals and Its Effect on the Required Force for Root Fracture
Success of Ultrasonic Technique in Removing Fractured
Rotary Nickel-Titanium Endodontic Instruments from Root
Canals and Its Effect on the Required Force for Root Fracture
Hasan Shahabinejad, DDS, MS, Amirreza Ghassemi, DDS, Lida Pishbin, DDS, MS,
and Arash Shahravan, DDS, MS
Introduction:
Fracture of rotary nickel-titanium files is
a real concern among endodontists; it affects the long-
term prognosis of treatment. Ultrasound is a favorable
technique for removing broken files, although it may
result in some complications. The aim of this study
was to determine the success rate of ultrasonic tech-
nique in removing file fragments and to evaluate its
influence on the force required to fracture a tooth
root.
Methods:
An in vitro study was carried out on
70 extracted maxillary premolars. In the experimental
group a #30/.04 taper Hero file was guided into the
canal to break and lodge therein. The lodged file was
removed by ultrasonic vibration and use of a dental
operating microscope. The canals were instrumented
with Hero files by using crown-down technique and
then obturated. All the teeth were prepared for mechan-
ical testing in Testometric machine to measure the
required force for root fracture. The Fisher exact test
and independent two-sample t test were used to
analyze data.
Results:
Ultrasonic technique exhibited
a success rate of 80% in removing broken files.
Success rate in the roots with file fracture before the
curve was 11.5 times more than that of file fracture
cases beyond the curve. Other factors such as bypass
possibility did not affect success rate. The average
time required for removing file fragments was 36.3
` 7.15 minutes, which did not significantly differ in
different file locations within the canal. According to
mechanical test results, ultrasonic application did not
significantly affect the required force for root fracture.
The force required to fracture a root did not signifi-
cantly differ in various file locations. Vertical fracture
in the buccolingual direction (split tooth) was the
most incident fracture pattern. Procedural errors
observed in this study predominantly included trans-
portation, perforation, and craze line.
Conclusions:
Ultrasonic technique was successful in removing 80% of fractured rotary files and did not significantly affect the required force for root
fracture.
(J Endod 2013;39:824–828)
Key Words
Fractured rotary endodontic instruments, removal, required force for root fracture,
ultrasonic technique
sexta-feira, 31 de maio de 2013
EEC / Prof. Carlos Bueno no Dental Canal (Belo Horizonte) 2013
O Prof. Carlos E. da Silveira Bueno esteve em Belo Horizonte
neste último dia 30 de maio
participando do Dental Canal 2013.
quarta-feira, 29 de maio de 2013
EEC/Prof. Carlos Fontana no IV Congreso Latino Americano de Líderes de Opinión Colténe / México - Lima HyFlex
Prof. Carlos Fontana esteve na compania dos amigos e também Professores Celso Kenji , Alexandre Câmara, Fernando dos Reis , Celso Caldeira, Marcelo Mangelli e Sônia Mendes.
Professora e ex-aluna do Curso de Mestrado em Endodontia da
EEC Patrícia Escobar (Paraguai) esteve no evento
Hands-on do Sistema Rotatório Hyflex CM
Prof. Antonis Chaniotis (Grécia) e Prof. Carlos Fontana (Equipe de Endodontia de Campinas)
Int Endod J maio 2013 - Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment
Abstract
Zuolo AS, Mello JE Jr, Cunha RS, Zuolo ML, Bueno
CES. Efficacy of reciprocating and rotary techniques for
removing filling material during root canal retreatment.
International Endodontic Journal.
To compare the efficacy of reciprocating and
rotary techniques with that of hand files for removing
gutta-percha and sealer from root canals.
Methodology
The root canals of fifty-four human
extracted maxillary central incisors were cleaned and
shaped using a crown-down technique to a size 40 and
filled with gutta-percha and a zinc oxide–eugenol-based
sealer using a lateral compaction technique. Teeth
were divided into three groups according to the
technique used for removing the root filling material:
group I – Gates–Glidden burs and stainless steel hand
files up to size 50; group II – rotary technique with
NiTi Mtwo R files and additional Mtwo files to size
50, 0.04 taper; group III – reciprocating technique
with the Reciproc instrument R50, size 50, 0.05
taper. Chloroform was used as a solvent in all groups.
Teeth were then split longitudinally and photo-
graphed under 89 magnification. The images were
transferred to a computer, and the total canal space
and remaining filling material were quantified. The
ratio of remaining filling material to root canal periphery was computed with the aid of Image Tool
3.0 software. The mean percentages of remaining
filling material and time required to remove it were
compared using the Kruskal–Wallis and Mann–Whitney
tests (P < 0.05).
Results
The mean percentage of remaining filling
material was significantly higher (P < 0.05) in group
II, with Mtwo rotary files (12.17%), than in group I,
with the hand file technique (7.19%), and group III,
with Reciproc instruments (4.57%), which were sta-
tistically similar (P > 0.05). The time required to
remove filling material was significantly shorter
(P < 0.05) in group III (194 s), followed by group II
(365 s) and group I (725 s) (P < 0.05).
Conclusion
Remaining endodontic filling material
was observed on the canal walls of all teeth regardless
of the technique used. Hand files combined with
Gates–Glidden burs (group I) and the reciprocating
technique (group III) removed more filling material
from the canal walls than the Mtwo R files. The recip-
rocating technique was the most rapid method for
removing gutta-percha and sealer, followed by the
rotary technique and the hand file technique.
Keywords: nickel–titanium, Reciproc files, reciprocat-
ing motion, root canal retreatment, rotary instruments.
Received 24 July 2012; accepted 2 February 2013
terça-feira, 28 de maio de 2013
domingo, 26 de maio de 2013
EEC no ENDO MEETING ABO-OSASCO 28/JUNHO
Participe e envie seu resumo concorrendo na categoria de
painéis de caso clínico ou trabalho científico !!!
International Endodontic Journal may 2013 - Shaping ability of different single-file systems in severely curved root canals of extracted teeth
Aim
To compare the shaping ability of three different
single-file systems with Mtwo rotary instruments dur-
ing the preparation of curved root canals in extracted
teeth.
Methodology
A total of 80 root canals with cur-
vatures ranging between 25° and 35° were divided
into four groups of 20 canals. Based on radiographs
taken prior to instrumentation, the groups were
balanced with respect to the angle and the radius of
canal curvature. Canals were prepared to the follow-
ing apical sizes: Mtwo: size 30 using the single-length
technique; Reciproc, F360, and OneShape: size 25.
Using pre- and post-instrumentation radiographs,
straightening of the canal curvatures was determined
with a computer image analysis programme. Prepara-
tion time, changes in working length, and instrument failures were also recorded.
Results
During preparation, no file fractured. All
instruments maintained the original canal curvature
well with no significant differences between the
instrument systems (P = 0.792). Instrumentation
with Reciproc and OneShape was significantly faster
than with F360 and Mtwo (P < 0.05), while F360
was significantly faster than Mtwo (P < 0.05). No
significant differences were obtained regarding
changes in working length during instrumentation
with the different instruments (P = 0.784).
Conclusion
Under the conditions of this study, all
instruments respected the original canal curvature
well and were safe to use. The use of Reciproc and
OneShape instruments required less time to prepare
the curved canals compared with Mtwo and F360.